Guide to Common Errors

This document is a quick guide to identify and fix failures in custom scripts on Monsta Tecnologia. If you encountered a runtime error or an unexpected return in a sensor, consult the categories below.

Structure of each topic:

  1. Error: Description of the symptom or log message.
  2. Likely Cause: What usually triggers this behavior.
  3. Solution: Step-by-step for correction.

CampoDescrição
ErroLua script runner timeout: deadline has elapsed
CausaThis error occurs when the Monsta execution engine stops the Lua script because it exceeded the allowed timeout for a sensor execution. By default, Monsta terminates scripts that take too long to respond to prevent the system from hanging or consuming excessive server resources.
SoluçãoGo to Configuration > Parameters and use the search field to find the key lua.timeout. The default value is 130 seconds. To change it, click Unlock, enter the new value and save.

CampoDescrição
ErroPagefile: Timeout connecting to xx.xx.xx.xx:xxxx stack traceback: [C]: in function ‘poll’ [string ”?”]:x: in function ‘connect’ [string “script”]:xxx: in function <[string “script”]:xxx> (tail call): in function <(tail call):-1>
CausaThis error indicates a failure when attempting to establish a network connection. The Lua script was able to start the call, but it timed out before the target device responded to the connection handshake. The “stack traceback” shows that the failure occurred exactly at the connection attempt (in function 'connect'), even before any data was sent or received.
SoluçãoEdit the device, go to Collection > WMI and increase the WMI Timeout field. Use the “Test” button to validate communication. Then save the changes. If the problem persists, other network-related factors may be preventing this communication. In that case, check your network for: • Firewall/Blocking: Is there a firewall rule at the destination or along the path (ACL, IPS) blocking the Monsta IP on the specified port. • Service Offline: The service you are trying to monitor (e.g., API, web server, database) is stopped or not listening on that specific port. • Unreachable Network: The Monsta server does not have a valid route to the destination IP. • Incorrect Port: The script is attempting to connect on a different port than the service uses. • Excessive Load on Destination: The target device has such high CPU that it cannot process new connection requests.

CampoDescrição
ErroTempo de Resposta: ping failed: Request timeout for icmp_seq x
CausaThis error occurs when Monsta sends an ICMP echo packet (the well-known “Ping”) to a device but does not receive the reply (Echo Reply) within the expected time.
SoluçãoThe monitored device did not respond to Monsta’s ICMP (ping) requests. 💡 Tip: If the equipment is on a network with high latency or packet loss, adjust the detection sensitivity. To do this, edit the device and go to Details > Sensitivity, changing the parameters according to the environment needs.

CampoDescrição
ErroSNMP timeout stack traceback: [C]: in function ‘poll’ [string robbery/snmp_checker]:xx: in function ‘getex’ [string “script”]:xx: in function ‘get’ [string “script”]:xx: in main chunk
CausaThis error occurs when the script attempts an SNMP read and the connection expires without receiving the requested data.
SoluçãoThe monitored device did not respond to Monsta’s SNMP requests. Edit the device, go to Collection > SNMP and increase the SNMP Timeout. Use the “Test” button to validate communication. Then save the changes. If the problem persists, check your network for: • Incorrect SNMP Community: The “Community String” (e.g., public or private) configured in Monsta does not match the one configured on the device. • Divergent SNMP Version: The device is using SNMP v2c while the script/configuration is trying v1 (or vice-versa), or there is an error in v3 credentials. • ACL or Firewall: The device has an access control list (ACL) that allows only specific IPs to perform SNMP queries, and Monsta’s IP is not included. • Blocked Port: UDP port 161 (SNMP default) is blocked on the path. • SNMP Agent Overload: The monitored device’s processor is so busy that the SNMP service (agent) cannot respond to the query in time.

CampoDescrição
ErroError converting to type: Float
CausaThis error occurs when the system expects a decimal number (Float) but received something it cannot convert to a number, such as an invalid text (String) or a null value (nil).
SoluçãoReview the monitor script to ensure the return does not contain strings (like commas or measurement units) in the value field. If the monitor shows normal readings but intermittently fails with this error, it is likely the device is returning a null (nil) value. This happens when there is no response to the query; in such cases, check the device logs for any failures.

CampoDescrição
Errowamp.error.no_such_procedure
CausaThis usually indicates that the **monkernel** service is not running on the Linux operating system where the software is installed. The monkerned service is important for the proper functioning of the software, and its inactivity prevents Monsta from executing necessary procedures.
SoluçãoThe solution involves ensuring the monkernel service is started. The user can choose between two main approaches to work around this situation: A. Reboot the System: The most comprehensive way to resolve most service startup issues is simply to reboot the Linux system where the software is installed. On reboot, the operating system will attempt to load and start all configured services, including monkernel, automatically. B. Start the Service Manually (Recommended): If rebooting is not viable or is time-consuming, the user can try to start the service directly using **systemctl**, which is the standard service management tool on many modern Linux distributions (like Ubuntu, Debian, CentOS, RHEL, etc.). Steps: 1. Open a Terminal (or use an SSH session) on the Linux server. 2. Run the following command to try to start the service: sudo systemctl start monsta-com.monkernel Note: This command requires superuser (sudo) permissions. After performing either action (rebooting the system or starting the service manually), you can check the service status to ensure it is active and running: systemctl status monsta-com.monkerned The ideal status should indicate **active (running)**

Ssh error occured: Key exchange init failed

Section titled “Ssh error occured: Key exchange init failed”
CampoDescrição
ErroSsh error occured: Key exchange init failed stack traceback
CausaThis error occurs during an SSH connection attempt between Monsta and a remote device (usually older models of switches, routers or radios). It indicates that Monsta and the device could not agree on which Key Exchange algorithm to use, because the device uses standards that are nowadays considered legacy or insecure by modern libraries.
SoluçãoMonsta uses state-of-the-art cryptographic libraries. The key exchange failure is a warning that your remote device is operating with obsolete security standards. The definitive fix is to update the monitored device so it supports secure cryptographic algorithms.

CampoDescrição
ErroNo route to host (os error 113) stack traceback
CausaThe os error 113 is an operating system network error code indicating that the destination host could not be reached. The operating system does not know which network interface should be used to send the packet to that specific IP.
SoluçãoTo resolve the error, ensure the system’s routing table has a valid path to the destination IP and that the default gateway is correctly configured to forward packets outside the local network.

Command not supported on legacy WMI probe, please update to the latest version

Section titled “Command not supported on legacy WMI probe, please update to the latest version”
CampoDescrição
ErroCommand not supported on legacy WMI probe, please update to the latest version
CausaThe probe or agent running is outdated and does not support the requested feature or command.
SoluçãoTo use this feature, you must update the probe. Visit our website (https://www.monsta.com.br), download the installer for the latest version from the downloads section and install it on the monitored equipment.

Powershell is not available: no agent or probe with min version 1.2.8 detected

Section titled “Powershell is not available: no agent or probe with min version 1.2.8 detected”
CampoDescrição
ErroPowershell is not available: no agent or probe with min version 1.2.8 detected
CausaThe probe or agent running is outdated and does not support the requested feature or command.
SoluçãoTo use this feature, you must update the probe. Visit our website (https://www.monsta.com.br), download the installer for the latest version from the downloads section and install it on the monitored equipment.

No agent or probe with min version 1.2.8 detected

Section titled “No agent or probe with min version 1.2.8 detected”
CampoDescrição
ErroNo agent or probe with min version 1.2.8 detected
CausaThe probe or agent running is outdated and does not support the requested feature or command.
SoluçãoTo use this feature, you must update the probe. Visit our website (https://www.monsta.com.br), download the installer for the latest version from the downloads section and install it on the monitored equipment.